Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Rev. bras. neurol ; 56(3): 5-10, jul.-set. 2020. tab, graf
Article in English | LILACS | ID: biblio-1120371

ABSTRACT

Total traumatic injury often requires surgical intervention such as neurotization using the phrenic nerve with the aim to recover the elbow function. However, its repercussions on the respiratory kinematics are unknown. Objective: To evaluate the ribcage volume in tricompartments division, kinematics of Duty Cycle, and shortening velocity of the respiratory muscles after nerve phrenic transfer. Methods: Five participants (4 male), aged 18 to 40 years old (32±2), diagnosed with total brachial plexus injury and with nerve phrenic transfer. The optoelectronic plethysmography (OEP) was the instrument to evaluate volume in quiet breathing (QB), inspiratory capacity (IC) and vital capacity (VC) of the rib cage in its tricompartments division (pulmonary rib cage, abdominal rib cage and abdomen rib cage) and in each hemithorax, as well as the shortening velocity of the respiratory muscles, and respiratory rate. Assessments occurred 30 days prior and 30 days after surgery. Results: There was a decrease in the total compartmental distribution in QB with statistical difference only in the abdominal compartment (p <0.05). Four patients showed a reduction in the shortening speed of the left diaphragm muscle. It was not possible to perform a group analysis of respiratory kinematics and volumes in CV, IC due to the variation found in each patient analyzed. Conclusion: There was a reduction in volume in the rib cage as well as a change in the speed of shortening of the respiratory muscles after the transfer of the phrenic nerve one month after surgery.


A lesão traumática total freqüentemente requer intervenção cirúrgica, como neurotização usando o nervo frênico, com o objetivo de recuperar a função do cotovelo. No entanto, suas repercussões na cinemática respiratória são desconhecidas. Objetivo: Avaliar o volume da caixa torácica na divisão dos tricompartimentos, a cinemática do Duty Cycle e a velocidade de encurtamento dos músculos respiratórios após a transferência do nervo frênico. Métodos: Cinco participantes (4 do sexo masculino), com idade entre 18 e 40 anos (32 ± 2), com diagnóstico de lesão total do plexo braquial e transferência do nervo frênico. A pletismografia optoeletrônica (OEP) foi o instrumento para avaliar o volume na respiração silenciosa (QB), a capacidade inspiratória (IC) e a capacidade vital (VC) da caixa torácica em sua divisão tricompartimental (caixa torácica pulmonar, caixa torácica abdominal e caixa torácica do abdômen ) e em cada hemitórax, bem como a velocidade de encurtamento dos músculos respiratórios e a frequência respiratória. As avaliações ocorreram 30 dias antes e 30 dias após a cirurgia. Resultados: Houve diminuição da distribuição compartimental total no QB com diferença estatística apenas no compartimento abdominal (p <0,05). Quatro pacientes apresentaram redução da velocidade de encurtamento do músculo diafragma esquerdo. Não foi possível realizar uma análise de grupo da cinemática respiratória e dos volumes em CV, IC devido à variação encontrada em cada paciente analisado. Conclusão: Houve redução do volume da caixa torácica e também alteração da velocidade de encurtamento dos músculos respiratórios após a transferência do nervo frênico um mês após a cirurgia.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Phrenic Nerve/surgery , Respiratory Muscles/physiopathology , Brachial Plexus/injuries , Nerve Transfer/methods , Plethysmography/instrumentation , Respiratory Function Tests/methods , Treatment Outcome
2.
Rev. Assoc. Med. Bras. (1992) ; 65(10): 1283-1289, Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1041037

ABSTRACT

SUMMARY Body composition assessment at the molecular level is relevant for the athletic population and its association with high performance is well recognized. The four-compartment molecular model (4C) is the reference method for fat mass (FM) and fat-free mass (FFM) estimation. However, its implementation in a real context is not feasible. Coaches and athletes need practical body composition methods for body composition assessment, and the bioelectrical impedance analysis method (BIA) is usually seen as a useful alternative. The aim of this study was to test the validity of BIA (Tanita, TBF-310) to determine the FM and FFM of elite judo athletes. A total of 29 males were evaluated in a period of weight stability using the reference method (4C) and the alternative method (Tanita, TBF-310). Regarding the 4C method, total-body water was assessed by deuterium dilution, bone mineral by DXA, and body volume by air displacement plethysmography. The slops and intercepts differed from 1 (0.39 and 1.11) and 0 (4.24 and -6.41) for FM and FFM, respectively. FM from Tanita TBF-310 overestimated the 4C method by 0.2 kg although no differences were found for FFM. Tanita TBF-310 explained 21% and 72% respectively in the estimation of absolute values of FM and FFM from the 4C method. Limits of agreement were significant, varying from -6.7 kg to 7.0 kg for FM and from -8.9 kg to 7.5 kg for FFM. In conclusion, TBF-310 Tanita is not a valid alternative method for estimating body composition in highly trained judo athletes.


RESUMO A avaliação da composição corporal ao nível molecular é relevante para a população esportiva e sua associação com o alto rendimento é bem reconhecida. O modelo molecular a quatro compartimentos (4C) é o método de referência para as estimativas de massa gorda (MG) e massa livre de gordura (MLG). No entanto, sua implementação no contexto real não é viável. Técnicos e atletas precisam de métodos práticos de composição corporal para a avaliação da composição corporal e o método de análise de impedância bioelétrica (BIA) é geralmente visto como uma alternativa útil. O objetivo deste estudo foi testar a validade da BIA (Tanita, TBF-310) na determinação de MG e MLG em atletas de elite de judô. Um total de 29 atletas masculinos foi avaliado em um período de estabilidade de peso usando o método de referência (4C) e o método alternativo (Tanita, TBF-310). Em relação ao método a 4C, a água corporal total foi avaliada pela diluição de deutério, mineral ósseo por DXA e volume corporal por pletismografia por deslocamento de ar. Os declives e interceções diferiram de 1 (0,39 e 1,11) e 0 (4,24 e -6,41) para MG e MLG, respectivamente. A MG da Tanita TBF-310 superestimou o método 4C em 0,2 kg, embora não tenham sido encontradas diferenças para MLG. A Tanita TBF-310 explicou 21% e 72%, respectivamente, na estimativa dos valores absolutos de MG e MLG do método a 4C. Os limites de concordância foram grandes, variando de -6,7 kg a 7,0 kg para MG e de -8,9 kg a 7,5 kg para MLG. Em conclusão, a TBF-310 Tanita não é um método alternativo válido para estimar a composição corporal em judocas altamente treinados.


Subject(s)
Humans , Male , Adolescent , Adult , Young Adult , Plethysmography/instrumentation , Body Composition , Models, Molecular , Martial Arts/physiology , Athletes , Reproducibility of Results , Electric Impedance
3.
Rev. argent. anestesiol ; 61(5): 275-279, sept.-oct. 2003. tab, graf
Article in Spanish | LILACS | ID: lil-397330

ABSTRACT

Introducción: la presión positiva al final de la espiración (PEEP) incrementa la capacidad residual funcional (CRF) en pacientes anestesiados, mientras que su efecto sobre la oxigenación es contradictorio. La estrategia de reclutamiento alveolar (ERA) demostró ser útil para normalizar la oxigenación y la mecánica respiratoria, aunque su efecto sobre la CRF no es conocido. Objetivo: evaluar el efecto de reclutamiento pulmonar sobre el volumen pulmonar medido con pletismografía. Lugar de aplicación: Hospital de la Comunidad (Mar del Plata). Diseño: estudio prospectivo. Población: se estudiaron 5 pacientes neuroquirúrgicos luego de una craneotomía. Métodos: se realizó una ERA aumentando y disminuyendo la presión inspiratoria pico (Pip) y la PEEP de modo secuencial en niveles de 25/0, 25/5, 30/10 y 40/15 cmH2O cada 8-10 ciclos respiratorios. La señal pletismográfica se registró continuamente y se midió el volumen pulmonar al fin de la espiración (VPFE), definido como la diferencia entre la línea de base entre un nivel de PEEP determinado y cero de PEEP. Se extrajo sangre arterial para su análisis gasométrico en el nivel de 25/5 cmH2O (antes y después de la ERA). Resultados: A niveles de presión 25/5 cmH2O, fue observado que en los 5 pacientes el VPFE y la PaO2 fueron superiores después de la ERA que antes de la misma. Conclusión: El efecto del reclutamiento pulmonar sobre la oxigenación y el volumen pulmonar fue superior al del mismo nivel de la PEEP sin reclutamiento.


Subject(s)
Humans , Male , Female , Anesthesia, General/adverse effects , Plethysmography/instrumentation , Plethysmography/methods , Positive-Pressure Respiration/methods , Craniotomy , Oxygen/blood , Prospective Studies , Pulmonary Alveoli , Pulmonary Atelectasis , Pulmonary Gas Exchange , Respiratory Mechanics , Tidal Volume
4.
Rev. colomb. neumol ; 9(1): 10-4, abr. 1997. tab
Article in Spanish | LILACS | ID: lil-190828

ABSTRACT

Introducción: La trombosis venosa profunda proximal de miembros inferiores (TVPPMI) es una entidad potencialmente mortal; de la rapidez del diagnóstico y la intervención depende el curso y complicaciones de la enfermedad. El diagnóstico por pletismografía de impedancia facilita el seguimiento y la conducta terapéutica; sin embargo, su sensibilidad y especificidad ha sido cuestionada y se propone el reemplazo por otros métodos no invasivos (doppler venoso). Objetivos: Determinar la sensibilidad y especificidad de la pletismografía de impedancia de miembros inferiores en el diagnóstico de la TVPPMI en pacientes con clínica o con factores de riesgo para esta enfermedad en el Hospital Universitario San Ignacio. Diseño: estudio de concordancia entre la venografía (patrón de oro) y la pletismografía de impedancia (IPG). Pacientes y Métodos: Entre febrero de 1994 y marzo de 1995 ingresaron 62 pacientes con clínica de TVPPMI o con factores de riesgo para la enfermedad al servicio de Medicina Interna o al Departamento del Radiología del Hospital Universitario San Ignacio. Se diligenció una historia clínica haciendo énfasis en los factores de riesgo y en el diagnóstico; se les realizó pletismografía de impedancia de miembros inferiores y posteriormente una venografía. Resultados: Se incluyeron 62 sujetos, de los cuales ocho se excluyen y se analizan un total de 54 pacientes. El 11 por ciento presentaban historia clínica de trombosis venosa profunda y el grupo restante, factores de riesgo para adquirir la enfermedad. La sensibilidad de la IPG en el diagnóstico de TVPPMI del grupo en general fue del 100 por ciento con especificidad de 92 por ciento, con un valor predictivo positico del 33 por ciento. En pacientes con sospecha clínica la sensibilidad fue del 100 por ciento y la especificidad del 90 por ciento; en pacientes sin clínica pero con factores de riesgo no se pudo calcular la sensibilidad y la especificidad fue del 90 por ciento. Conclusión: En pacientes con sospecha clínica de TVPPMI, la IPG tiene alta sensibilidad como método diagnóstico; su valor predictivo positivo en este estudio es bajo por el tamaño de la muestra. Se debe continuar el estudio incluyendo más pacientes con clínica o con alto riesgo de tener TVPPMI.


Subject(s)
Humans , Plethysmography , Plethysmography/instrumentation , Plethysmography/standards , Plethysmography/trends , Plethysmography/statistics & numerical data , Plethysmography, Impedance/instrumentation , Plethysmography, Impedance/methods , Plethysmography, Impedance/standards , Plethysmography, Impedance/trends , Plethysmography, Impedance , Thrombosis , Thrombosis/diagnosis , Venous Insufficiency/diagnosis
5.
Bol. méd. Hosp. Infant. Méx ; 54(1): 47-53, ene. 1997. tab, ilus
Article in Spanish | LILACS | ID: lil-219604

ABSTRACT

Las pruebas de función respiratoria son una serie de parámetros para valorar la función broncopulmonar y para su realización se cuenta con instrumentos como el espirómetro y pletismógrafo. Dentro de sus indicaciones están: evaluar la gravedad de los padecimientos pulmonares y/o sus secuelas; evaluar riesgo preoperatorio y pronóstico en cirugía de tórax y abdomen alto; valorar la eficacia del tratamiento; describir la evolución de la enfermedad; monitorear reacciones adversas a medicamentos. Además, permiten realizar pruebas de reto bronquial para diagnóstico de hiperreactividad en vías aéreas. Actualmente se cuenta con flujímetros portátiles con los que se obtienen mediciones cuantitativas de las vías aéreas para monitoreo extrahospitalario, permitiendo detectar la respuesta al tratamiento de acuerdo a un sencillo esquema denominado del semáforo. La compresión de la fisiología pulmonar y el uso de instrumentos para su valoración pueden contribuir de manera importante al cuidado del paciente con enfermedad respiratoria


Subject(s)
Pediatrics , Plethysmography/instrumentation , Spirometry/instrumentation , Respiratory Function Tests/statistics & numerical data , Respiratory Function Tests/methods
6.
Indian J Physiol Pharmacol ; 1991 Jan; 35(1): 52-4
Article in English | IMSEAR | ID: sea-107516

ABSTRACT

A method of plethysmography which does not require an air/water tight chamber is described. The method is sensitive enough to record microlitre volumes/volume changes. Its application in two situations, viz. in experimental (artificial) edema and blood flow measurement in the human hand has been demonstrated.


Subject(s)
Animals , Edema/physiopathology , Foot/blood supply , Hand/blood supply , Humans , Plethysmography/instrumentation , Rats , Regional Blood Flow/physiology
SELECTION OF CITATIONS
SEARCH DETAIL